Em385 - CICB’s four-day program for US Army Corps of Engineers (USACE) EM 385-1-1 Training has been developed with the objectives to assist USACE personnel, contractors or management and employers achieve and maintain compliance with this comprehensive standard. This manual applies to Headquarters, US Army Corps of Engineers elements, …

 
Common Challenges in EM385 Compliance . If your business is working with government facilities, you will need to be familiar with the EM 385 safety and health requirements. One of the most important requirements in EM 385 is for the contractor to develop a project-specific Accident Prevention Plan (APP).. Urdu language to english

EM 385-1-1 - Army Corps of Engineers Safety and Health Requirements Documents. Engineering Manual (EM) 385-1-1 is a comprehensive set of safety and health standards required for all operations that services and operations that are subject to OSHA's construction standard (29 CFR 1926.11).período, a produção agrícola aumentou em 385% enquanto a área agrícola aumentou somente 32%. Este processo de transformação da agropecuária não é fruto do acaso. Ele é o resultado de décadas de inovação e desenvolvimento de uma agricultura adaptada aos trópicos, com contínuos ganhos de produtividade e intensificação da ...EM-385 is the code for the safety and health requirements written and constantly updated by the US Corps of Engineers and is meant to regulate DoD projects. This manual very much resembles OSHA, which should not come as a surprise, since both codes are meant to promote occupational health and safety. For instance, both OSHA and EM-385 require ...EM 385-1-1 XX Jul 14 20-5 20.A.16 Except where automatic shutoff valves are used, safety lashings or suitable double action locking devices shall be used at connections to machines of high pressure hose lines and between high pressure hose lines. 20.A.17 Connections with high pressure hoses must be secured with a safety lashing/whip check: a. EM 385-1-1 XX Jul 14 21-4 . a. be trained appropriately; b. advise and provide guidance for managers, employees and others on all matters pertaining to their Fall Protection Program; c. establish all duties and responsibilities required by the Fall Protection Program and assign them to individuals who are trained and qualified to perform them; d. What is EM 385 fall protection competent person training? EM 385 is the Engineer’s Manual released by the U.S. Army Corps of Engineers outlining the health and safety standards …EM 385-1-1 3 Nov 03 Q-4 Anchorage: a secure point of attachment for lifelines, lanyards, deceleration devices, or tiebacks. Anchored bridging: the steel joist bridging is connected to a bridging terminus point. Anti-runaway: a safety device to stop a declining conveyor in case of mechanical or electrical failure.The EM 385-1-1 manual was designed by USACE, in collaboration with NAVFAC, and provides an overview of the safety requirements on federal projects. The 2014 Edition supersedes the last edition of EM 385-1-1 published in 2008. While many of the requirements in the EM 385-1-1 align with OSHA Standards, some specific requirements …EM 385-1-97: CESO-E: Explosives - Safety and Health Requirements Manual: 5/17/2013: Page 1 of 1: First Previous [1] Next Last: Publication Change Request Form . ESSAYONS. Our Mission. Deliver vital engineering solutions, in collaboration with our partners, to secure our Nation, energize our economy, and reduce disaster risk. EM 385-1-1 XX Jul 14 Q-1 APPENDIX Q . Definitions . This appendix defines the following terms for the purposes of this manual. Abrasive blasting: the forcible application of an abrasive to a surface by pneumatic pressure, hydraulic pressure, or centrifugal force. Absorbed dose: energy imparted to matter by ionizing radiation per unit mass of EM 385-1-1 Course Overview This 40-Hour EM 385-1-1 course is crucial for maintaining a safe and efficient work environment on military jobsites. We provide information relative to the 2014 US Army Corps Safety and Health Requirements Manual, EM385-1-1 and pertinent Occupational Safety and Health Administration (OSHA) construction standards. EM 385-1-1 30 Nov 14 27-3 d. Plumbing-up guys shall be removed only under the supervision of a Competent Person (CP). e. Measures shall be taken to prevent unrolled wire mesh from recoiling. 27.B. 03 Post-tensioning operations. a. No employee (except those essential to the post-tensioning operations) shall beTemporary, destroy when no longer needed. This material is an informational copy. See proponent for official copy. CONTENTdm number. 54. CONTENTdm file name. 55.cpd.SUMMARY: The U.S. Army Corps of Engineers (USACE) Safety and Health Requirements Manual (EM 385–1–1) is the gold standard for Safety and Occupational Health regulations. The manual holds a long history dating back to 1941 and is designed to facilitate the standardization of all safety programs. The EM 385–1–1 prescribes the …In general terms, if the project involves USACE or other federal agencies, EM385 training is mandatory for SSHOs and other key personnel. If the project does not involve USACE or other federal agencies, OSHA 30 training could be sufficient for safety supervisors and managers. However, some government clients may still require EM385 …EM 385-1-1 XX Jul 14 15-1 SECTION 15 . Rigging . 15.A General. 15.A.01 Inspection and use. a. Rigging equipment shall be inspected as specified by the manufacturer, by a Competent Person (CP), before use on each shift as necessary during its use to ensure that it is safe. The CP must have training and experience equivalent to, or be under theAUGUSTA, GA –Dec. 13, 2023 – Impact Safety, a leader in workplace safety training, is proud to announce the launch of their EM 385 Fall Protection Training, a comprehensive course designed to enhance safety in the construction industry. This three-day course is an essential resource for businesses across all sectors seeking to ensure a safe working …入札公告日に有効な、em 385-1-1 の最新版 (暫定的な変更を含む) を遵守しなければならない。 応札の前に入札者は、hqusace の労働安全衛生ウェブサイト (c. 参照) で、最新の変更点を確 認すべきである。EM 385-1-1 30 Nov 14 22-4 22.B.06 Anyone involved in erecting, disassembling, moving, operating, using, repairing, maintaining or inspecting a scaffold shall be trained by a CP to recognize any hazards associated with the work in question. Proof of training shall be maintained on site and made available to the GDA upon request.EM 385-1-1 3 Nov 03 Q-4 Anchorage: a secure point of attachment for lifelines, lanyards, deceleration devices, or tiebacks. Anchored bridging: the steel joist bridging is connected to a bridging terminus point. Anti-runaway: a safety device to stop a declining conveyor in case of mechanical or electrical failure.EngineerManuals/EM _385-1-1.pdf . Author: Stafford, Nicholas J CIV USARMY CESAM \(US\) Created Date: 8/22/2018 9:51:37 AM ... www.publications.usace.army.mil Official Publications of the Headquarters, U.S. Army Corps of ... EM 385 Training. 24 Hours 15 Modules. Details. Beginner. Free Course Environmental Management Systems (5.00) CSP Exam Prep. 6 Modules. Details. Proficient. Free Course Ergonomics (5.00) ASP Exam Prep. 6 ...EM 385-1-1 XX Jul 14 11-4 b. For maintenance and construction activities, all portable flexible cords or cables (i.e, extension cords) shall be inspected by the user of the cord at least daily. c. Portable flexible cords shall contain the number of adequately sized conductors required for the load plus an adequately sized equipment ground ... EM 385-1-1 30 Nov 14 29-2 29.A.03 All persons working with explosives shall be in good physical condition and be able to understand and give written and verbal orders. Mar 28, 2024 · EM 385 incorporates provisions that are virtually identical to OSHA's general industry standard directly into the requirements outlined in section 6.1. Additonal Requirements. In addition to technical requirements that are more rigorous than OSHA standards, EM 385 includes a few requirements that are not even addressed by OSHA standards. EM 385-1-1, Safety and Health Requirements Manual. (November 30, 2014). Chapter 23 - Demolition. Appendix A - Minimum Basic Outline for Accident Prevention Plans. Example Checklist (PDF) from USACE Galveston District. Contractor Accident Prevention Plan (APP) Checklist (PDF).EM 385-1-1 3 Nov 03 Q-4 Anchorage: a secure point of attachment for lifelines, lanyards, deceleration devices, or tiebacks. Anchored bridging: the steel joist bridging is connected to a bridging terminus point. Anti-runaway: a safety device to stop a declining conveyor in case of mechanical or electrical failure.O PRESIDENTE DA REPÚBLICA, faço saber que o Congresso Nacional decreta e eu sanciono a seguinte Lei:. CAPÍTULO I. Características e Natureza da Companhia ou Sociedade Anônima. Características Art. 1º A companhia ou sociedade anônima terá o capital dividido em ações, e a responsabilidade dos sócios ou acionistas será limitada …D82385. Subchefia para Assuntos Jurídicos. DECRETO N o 82.385, DE 5 DE OUTUBRO DE 1978. Regulamenta a Lei nº 6.533, de 24 de maio de 1978, que dispõe sobre as profissões de Artista e de Técnico em Espetáculos de Diversões, e dá outras providências. O PRESIDENTE DA REPÚBLICA.EM 385-1-1 forms and informational material for reference and review. USACE EM 385-1-1 2014 PDF, USACE Coy Fax Form, EM 385-1-1 book purchase, etc.EM 385-1-1, Safety and Health Requirements Manual. You can download a copy of the Complete EM 385-1-1, 2014 Version or it can be accessed through the USACE Official …EM385-specific version takes our most popular course to the next level by putting you in compliance with the latest EM385 standards. This course includes in-class lectures with slides and video as well as hands-on scenarios applying theory discussed to practical workplace situations. It is a pass/fail program incorporating both written andMar 13, 2019 · The APP/SSHP must address all occupational safety and health hazards (traditional construction as well as contaminant related hazards) associated with environmental cleanup activities. The APP/SSHP must cover each SSHP element in section 33.B of EM 385-1-1 and each APP element in Appendix A of EM 385-1-1. CICB Senior Instructor Larry Kime introduces us to EM385-1-1. Larry reminds us that contractors on a military installation must be aware of more than the OSHA regulations and ANSI/ASME standards. US Army Corps of Engineers (USACE) EM385-1-1 is a broad range safety standard written into any contract for contractors on a military installation.provide policy, programs, technical services, oversight and outreach related to safety and occupational health matters in support of USACE missions worldwide.CICB’s four-day program for US Army Corps of Engineers (USACE) EM 385-1-1 Training has been developed with the objectives to assist USACE personnel, contractors or management and employers achieve and maintain compliance with this comprehensive standard. This manual applies to Headquarters, US Army Corps of Engineers elements, … EM 385-1-1 XX Jul 14 4-3 e. Beds, cots, or bunks, and suitable storage facilities (such as wall lockers for clothing and personal articles) shall be provided in every room used for sleeping purposes. Beds shall be spaced not closer than 3 ft (1 m) both laterally and end-to-end and shall be elevated at least 1 ft (.3 m) from the floor. The TITAN University USACE – NAVFAC EM 385-1-1, 40-hour training course, along with the downloaded course materials manual, covers SSHO requirements, as well as on-site safety and health requirements for all USACE and NAVFAC construction activities and operations. Learn from the people successfully performing the onsite safety and quality ...Contractors have asked for nationalized consistency for implementation of SOH requirements. Everyone should be implementing t\൨e same requirements which are … 8-Hour EM 385-1-1 Refresher Training. The 8-Hour EM 385-1-1 online refresher course is designed to keep Site Safety Health Officers (SSHOs), military contractors and government employees compliant with annual refresher training requirements from the U.S. Army Corps of Engineers. $99. EM 385-1-1 Course Overview This 40-Hour EM 385-1-1 course is crucial for maintaining a safe and efficient work environment on military jobsites. We provide information relative to the 2014 US Army Corps Safety and Health Requirements Manual, EM385-1-1 and pertinent Occupational Safety and Health Administration (OSHA) construction standards. The EM 385-1-1 Safety & Health Topics (EM385) course helps ensure Site Safety and Health Officers (SSHOs) and others stay compliant with the USACE Safety and Health …EM 385-1-1 - Army Corps of Engineers Safety and Health Requirements Documents. Engineering Manual (EM) 385-1-1 is a comprehensive set of safety and health standards required for all operations that services and operations that are subject to OSHA's construction standard (29 CFR 1926.11).EM 385-1-1 30 Nov 14. 24-12 b. Carabiners and snap hooks: Used for climbing (life support) shall have at least two consecutive, deliberate actions to prepare the gate for opening and shall be rated at 5,000 lbs (22.2kN) and shall meet the ANSI/ASSE Z359 Fall Protection Code. Gates shall be rated at 3600 lbs (16kN).CICB Senior Instructor Larry Kime introduces us to EM385-1-1. Larry reminds us that contractors on a military installation must be aware of more than the OSHA regulations and ANSI/ASME standards. US Army Corps of Engineers (USACE) EM385-1-1 is a broad range safety standard written into any contract for contractors on a military installation.provide policy, programs, technical services, oversight and outreach related to safety and occupational health matters in support of USACE missions worldwide. Temporary, destroy when no longer needed. This material is an informational copy. See proponent for official copy. CONTENTdm number. 54. CONTENTdm file name. 55.cpd. EM 385-1-1 XX Jul 14 28-1 . SECTION 28 . Steel Erection . 28.A General. The fall protection threshold height requirement is 6 ft (1.8 m) for ALL work covered by this manual, unless specified differently below, whether performed by Government or Contractor work forces, to include steel erection activities and systems-The AGC San Diego Training Campus features 15+ hands-on simulators, providing students with real-world safety training and situations for the for the three-day Fall Protection training course. Additional training programs offered include: Confined Space Entry Training. CPR, First Aid and AED Training . OSHA Safety Training. Official Publications of the Headquarters, U.S. Army Corps of ... This course is the first of five parts in the 40-hour Hazard Awareness Course for Contractors. It covers requirements detailed within the first 6 sections of EM 385-1-1 (2014). The 5-course program will help all managers, supervisors, contractors, or construction personnel working on U.S. military contracts and any worker needing to be ...O PRESIDENTE DA REPÚBLICA, faço saber que o Congresso Nacional decreta e eu sanciono a seguinte Lei:. CAPÍTULO I. Características e Natureza da Companhia ou Sociedade Anônima. Características Art. 1º A companhia ou sociedade anônima terá o capital dividido em ações, e a responsabilidade dos sócios ou acionistas será limitada …Fast EM385-1-1 Certification Online. Our training gets you EM385-1-1 certified online fast and hassle free. Register, take a course on your laptop, tablet or phone and train at your own pace. Get your instant EM385 1-1 Certificate with QR Code Verification immediately upon completion. Satisfy U.S. Army Corps of Engineers (USACE) training ...The TITAN University USACE – NAVFAC EM 385-1-1, 40-hour training course, along with the downloaded course materials manual, covers SSHO requirements, as well as on-site safety and health requirements for all USACE and NAVFAC construction activities and operations. Learn from the people successfully performing the onsite safety and quality ...We’ve been trusted by millions of learners to provide their regulatory-approved training. You get simple to follow course content that you can access anytime, anywhere. We're here for you with online chat and toll-free phone support. You’re in good hands. We’ve been in business for over 25 years. Shop for site safety and health officer ...EM 385-1-1 30 Nov 14 . 10-5 . e. Workers may be exposed to hazardous concentrations of chromium (VI) while welding, cutting or performing hot work on stainless steel, high chrome alloys or chrome-coated metal, or during the application and removal of chromate-containing paints and other surface coatings. > See Section 06.L. f.This guide was designed to detail the significant changes from the 2014 edition of the EM 385-1-1 to the 2024 edition of the EM 385-1-1 which is effective March 15, 2024. The USACE has drastically revised this safety manual including but not limited to the name, numbering system, and paragraph structure. This manual us. EM 385-1-1 30 Nov 14 16-2 h. Operators of equipment with a maximum manufacturer -rated hoisting/lifting capacity of 2,000 pounds (907 kg) or less, are exempt from the operator qualification or certification requirements in Sections 16.B.02 through 16.B.05 only. In addition, this equipment may not be used to hoist personnel ; i. CESO. Radiation Protection Manual. 9/30/2013. EM 385-1-97. CESO-E. Explosives - Safety and Health Requirements Manual. 5/17/2013. EM 385-1-1 XX Jul 14 4-3 e. Beds, cots, or bunks, and suitable storage facilities (such as wall lockers for clothing and personal articles) shall be provided in every room used for sleeping purposes. Beds shall be spaced not closer than 3 ft (1 m) both laterally and end-to-end and shall be elevated at least 1 ft (.3 m) from the floor. Contractors have asked for nationalized consistency for implementation of SOH requirements. Everyone should be implementing t\൨e same requirements which are those found in the EM 385-1-1. These are USACE standards and those to which contractors and othe對rs learn and train to \⠀栀漀瀀攀昀甀氀氀礀尩.EM 385-1-1 XX Jul 14 15-1 SECTION 15 . Rigging . 15.A General. 15.A.01 Inspection and use. a. Rigging equipment shall be inspected as specified by the manufacturer, by a Competent Person (CP), before use on each shift as necessary during its use to ensure that it is safe. The CP must have training and experience equivalent to, or be under the Official Publications of the Headquarters, U.S. Army Corps of ... EM 385-1-1 30 Nov 14 14-5 14.C.05 Material storage shall be in compliance with manufacturer’s recommendations. 14.C.06 Materials stored inside buildings under construction shall not be placed within 6 ft (1.8 m) of any hoistway or floor opening, or within 10 ft (3 m) of an exterior wall that does not extend above the material s stored. LEI Nº 11.638, DE 28 DE DEZEMBRO DE 2007. Altera e revoga dispositivos da Lei no 6.404, de 15 de dezembro de 1976, e da Lei no 6.385, de 7 de dezembro de 1976, e estende às sociedades de grande porte disposições relativas à elaboração e divulgação de demonstrações financeiras. O PRESIDENTE DA REPÚBLICAFaço saber que o …This complete EM 385-1-1 training course is 40 hours. However, don’t let that scare you. All TITAN University Courses can be taken wherever you want, whenever you want, as long as you can connect to the internet. You can stop and start whenever you like and we’ll save your place. In addition, students can also choose to take 8-Hour EM 385 ... EM 385-1-1 (including interim changes) that is in effect on the date of solicitation. Prior to making an offer, bidders should check the HQUSACE Safety and Occupational Health web site (see paragraph c) for the latest changes. No separate payment will be made for compliance with this paragraph or for compliance with other safety EM 385-1-1 30 Nov 14 9-3 09.A.11 Measures must be taken to control the growth of tall grass, brush, and weeds adjacent to facilities. A break of at least 3 ft (0.9 m) shall be maintained around all facilities. 09.A.12 Paint-soiled clothing and drop cloths, when not in use, shall be stored in well-ventilated steel cabinets or containers. 09.A. EM 385-1-1 XX Jul 14 Q-1 APPENDIX Q . Definitions . This appendix defines the following terms for the purposes of this manual. Abrasive blasting: the forcible application of an abrasive to a surface by pneumatic pressure, hydraulic pressure, or centrifugal force. Absorbed dose: energy imparted to matter by ionizing radiation per unit mass ofApr 14, 2022 · SUMMARY: The U.S. Army Corps of Engineers (USACE) Safety and Health Requirements Manual (EM 385–1–1) is the gold standard for Safety and Occupational Health regulations. The manual holds a long history dating back to 1941 and is designed to facilitate the standardization of all safety programs. The EM 385–1–1 prescribes the safety and ... Acknowledge the risks and assign a Risk Assessment Code (RAC). Review every hazard and assess the risk in terms of: Probability – frequent, likely, occasional, seldom or unlikely. Severity – catastrophic, critical, marginal or negligible. Use the RAC matrix on EM 385-1-1 to assess the hazards and determine the overall risk assessment …There are several EM 385-1-1 courses to choose from. They vary in length, and which one you need depends on your role. Most workers need the 16-Hour EM 385 …EM 385-1-1 XX Jul 14 5-2 b. When the employer has reason to believe that any affected employee who has been trained does not have the understanding and skill required for the use of the PPE, the employer shall make certain that the employee receives the necessary re-training to acquire the appropriate skills. c.LEI Nº 6.533, DE 24 DE MAIO DE 1978. Dispõe sobre a regulamentação das profissões de Artistas e de técnico em Espetáculos de Diversões, e dá outras providências. O PRESIDENTE DA REPÚBLICA , faço saber que o CONGRESSO NACIONAL decreta e eu sanciono a seguinte Lei: Art . 1º - O exercício das profissões de Artista e de Técnico em ...EM 385-1-1 XX Jul 14 15-1 SECTION 15 . Rigging . 15.A General. 15.A.01 Inspection and use. a. Rigging equipment shall be inspected as specified by the manufacturer, by a Competent Person (CP), before use on each shift as necessary during its use to ensure that it is safe. The CP must have training and experience equivalent to, or be under theQuestions answered "NO" are to be entered into the Site Safety and Occupational Health Deficiency Tracking System for correction (Refer to EM 385-1-1 01.A.12.d) Preparatory Phase/ORM Planning. 1. Accepted Accident Prevention Plan (APP) on-site and updated to reflect current management?EM 385-1-1 XX Jul 14 4-3 e. Beds, cots, or bunks, and suitable storage facilities (such as wall lockers for clothing and personal articles) shall be provided in every room used for sleeping purposes. Beds shall be spaced not closer than 3 ft (1 m) both laterally and end-to-end and shall be elevated at least 1 ft (.3 m) from the floor.The USACE EM 385-1-1 applies to all construction contract work awarded under the provisions of FAR Clause 52.236-13. Interestingly, all new contracts for maintenance, service, research and development, and supply, as well as, contracting actions for hazardous, toxic, and radioactive waste site investigation, design, or … EM 385-1-1 (including interim changes) that is in effect on the date of solicitation. Prior to making an offer, bidders should check the HQUSACE Safety and Occupational Health web site (see paragraph c) for the latest changes. No separate payment will be made for compliance with this paragraph or for compliance with other safety

Course content complies with the requirements within OSHA 1926.32(f), 1926.500, 1910 ANSI/ASSE Z359.2 code. (EM 385-1-1, updated March 2015) (24-hours) standards. Additionally, this course will prepare the participant with the knowledge and skills to perform the annual inspection and record-keeping under these standards.. Real alcazar seville

em385

This manual applies to Headquarters, US Army Corps of Engineers (HQUSACE) elements, major subordinate commands, districts, centers, laboratories, and field operating …EM 385-1-1 XX Jul 14 3-1 SECTION 3 . Medical and First Aid Requirements . 03.A General. 03.A.01 Prior to the start of work by a contractor and for all USACE locations, arrangements shall be made for medical facilities and personnel to provide prompt attention to injured employees. For work or tasks with a high or extremely high riskEM 385-1-1 XX Jul 14 28-1 . SECTION 28 . Steel Erection . 28.A General. The fall protection threshold height requirement is 6 ft (1.8 m) for ALL work covered by this manual, unless specified differently below, whether performed by Government or Contractor work forces, to include steel erection activities and systems-Students will have practical experience completing an AHA and APP. This course meets and/or exceeds the requirements of the UFGS (2010) 01 35 26 for Key Contractor Personnel. Course Length: Four 10-Hour Days. OSHA 30 Certification is included in this course. EM385-1-1 40 Hour Construction Safety Course with OSHA 30.EM 385-1-1, Safety and Health Requirements Manual. You can download a copy of the Complete EM 385-1-1, 2014 Version or it can be accessed through the USACE Official …入札公告日に有効な、em 385--1 1の最新版 (暫定的な変更を含む) を遵守しなければならない。 応札の前に入札者は、hqusace の労働安全衛生ウェブサイト (c. 参照) で、最新の変更点を確 認すべきである。The manual holds a long history dating back to 1941 and is designed to facilitate the standardization of all safety programs. The EM 385–1–1 prescribes the safety and health requirements for all Corps of Engineers activities and operations. The USACE is soliciting comments on the proposed revisions to EM 385–1–1. DATES: EM 385-1-1 30 Nov 14 29-2 29.A.03 All persons working with explosives shall be in good physical condition and be able to understand and give written and verbal orders. This three-day course educates students on the various components of a worksite fall protection program and will also help develop the skills required of a Competent Person. Participants will learn course content through a combination of direct classroom instruction and multiple workshops. For individuals who do not require EM385 Competent ...EM 385-1-1 XX Jul 14 33-2 c. Hazardous waste operations performed by Government personnel do not require development of an APP, but do require a Project Safety and Health Plan and a SSHP in compliance with Section 01.A.09 and local safety and health policies for in-house activities. All activities shall comply with the written SSHP.Course content complies with the requirements within OSHA 1926.32(f), 1926.500, 1910 ANSI/ASSE Z359.2 code. (EM 385-1-1, updated March 2015) (24-hours) standards. Additionally, this course will prepare the participant with the knowledge and skills to perform the annual inspection and record-keeping under these standards.This manual applies to Headquarters, US Army Corps of Engineers (HQUSACE) elements, major subordinate commands, districts, centers, laboratories, and field operating …Temporary, destroy when no longer needed. This material is an informational copy. See proponent for official copy. CONTENTdm number. 54. CONTENTdm file name. 55.cpd.Mar 13, 2019 · The APP/SSHP must address all occupational safety and health hazards (traditional construction as well as contaminant related hazards) associated with environmental cleanup activities. The APP/SSHP must cover each SSHP element in section 33.B of EM 385-1-1 and each APP element in Appendix A of EM 385-1-1. EM 385-1-1 30 Nov 14 2 4. General. a. The provisions of this manual implement and supplement the safety and health standards and requirements referenced above. Where … CESO. Radiation Protection Manual. 9/30/2013. EM 385-1-97. CESO-E. Explosives - Safety and Health Requirements Manual. 5/17/2013. DEPARTMENT OF THE ARMY EM 385-1-1 U.S. Army Corps of Engineers CESO-ZA Washington, D.C. 20314-1000 For sale by the U.S. Government Printing Office Superintendent of Documents, Mail Stop: SSOP, Washington, DC 20402-9328 ISBN 0-16-048877-x Manual No. 385-1-1 3 November 2003 Safety SAFETY AND HEALTH REQUIREMENTS 1. EM 385-1-1 30 Nov 14 14-5 14.C.05 Material storage shall be in compliance with manufacturer’s recommendations. 14.C.06 Materials stored inside buildings under construction shall not be placed within 6 ft (1.8 m) of any hoistway or floor opening, or within 10 ft (3 m) of an exterior wall that does not extend above the material s stored.EM 385-1-1 30 Nov 14 . 10-5 . e. Workers may be exposed to hazardous concentrations of chromium (VI) while welding, cutting or performing hot work on stainless steel, high chrome alloys or chrome-coated metal, or during the application and removal of chromate-containing paints and other surface coatings. > See Section 06.L. f..

Popular Topics